pxie-4142. Hardware Services. pxie-4142

 
Hardware Servicespxie-4142  Refer to the NI

It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe-4142 제품 인증 - NI 홈 페이지로 돌아가기pxie-2512 PXIE-1435 Company advantage service: 1. Fax: (240) 376-1381. com. pxie-4142 pxie-4143 pxie-4144 pxie-4145 pxie-4162 pxie-4163 問題敘述 我想使用多個smu模擬串聯連接的電池。由於我需要在電池模塊中模擬堆疊整個串聯的電池單元,因此我想串聯連接多個smu,因此每個smu將代表一個電池單元。. The device has a 25–point D–SUB and male front panel connector. This page provides dimensional drawings for the PXIe-4142. Supply Ability: 10000 Piece/Pieces per Month. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Existing code created with earlier versions of NI‑DCPower and that contains Express VIs will continue to execute, but the Express VI cannot be reconfigured from a dialog box. •Current Sesitivity: 10 pA. This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source Measure Unit (SMU). • Device front panel—The PXIe-4135 (40W) shows PXIe-4135 40W System본 페이지는 PXIe-4142 의 치수도면을 제공합니다. The NI 4138/4139 can also be stacked in series or parallel for extended output capabilities. The NI PXIe-4138 is a single channel Source Measure Unit that consolidates a digital control loop design with. PXIe-4163 Issue Details I would like to connect multiple SMU channels in parallel, so I can increase the available amount of current. PXIe-4142の分解能は、アパーチャ遅延が100 µsに設定されていると、1,000 ppmに なります。24 Vレンジの分解能は、次の式に示すように、24Vを1,000 ppmで乗算 して計算します。 24 V * 1,000 ppm = 24 V * 1,000 * 1 × 10-6 = 24 mV The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. For more information please refer to Cascading the Outputs of the NI PXIe-4138/4139. If I understand you correctly, you want to output a sequence on one channel (of a PXIe-4139) and read back data on another channel (on a PXIe-4142). the PXIe-4142. •Source Adapt: Yes. Each SMU offers 4-quadrant operation to source or sink up to ±24 V at ±150 mA. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. You can request. 1 μA. The NI PXIe-4142/43 source measure units (SMUs) are high-channel-count, high-speed SMUs with four identical SMU channels per PXI Express slot. PXIe-4142 PXIe-4138 PXIe-4112 PXIe-4113 Power Supply Software. Thank you for your participation! * Your assessment is very important for improving the workof artificial intelligence, which forms the content of this projectPXIe-5668 Controller module, NI, PXIe-5668 Controller module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. 2. Page 1: Table Of Contents. PXIe-4144. Options. National Instruments NI PXIe-4142 ; National Instruments NI PXIe-4463 ; National Instruments Categories. The idea is to set the measuring channel's Source Mode to DC Current and set 0A for the current level (or as close. Hardware Services. Member. The PXIe‑4138 (Part Number: 782856-01) Source Measure Unit (SMU) conveys high power, exactness, and speed. It combines vector signal generator, vector signal analyzer and high-speed serial interface capabilities with FPGA-based real-time signal processing and control. Part Number: 784483-01. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Re: Recommended approach for PXI control from Python eperez. 47 KB We offer many of our products to test drive in your specific application, simply fill in the short form below, one of our technical application engineers will call you to discuss. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Set the level on the NI 4142 to the first specified test point. PXIe-4145. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. Diversified models and products, and all kinds of rare and discontinued products 4. 2. Environment. Here, you can click the Chassis tab and select the PXI Express Chassis you are interested in purchasing. 尽管未将DCPower和SMU卡(如PXIe-4139)设计为用作功能或波形发生器,但可以通过将所需的频率和幅度或预定义的任意波形转换为频率来对卡进行编程以输出标准功能适当设置电压电平和源延迟(通过特定硬件的采样间延迟校正)的连续输出序列。. PXIe-4142 Product Certification(s) PXIe-4142 Letter of Volatility. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. The PXIe-5655 RF Analog Signal Generator can supply the PXIe-5841 with enhanced local oscillators (LOs) that decrease phase noise. Note Before you begin, install and configure your chassis and controller. In LabVIEW, create a new VI by going to File >> New VI. As an example, assume you are using a PXIe-4139 in Single Point source mode. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. A valid service agreement may be required. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. PXI-7842R Controller module, NI, PXI-7842R Controller module PXI-7842R Controller module Module Clips Drive controller servo motor Contact: Mr. com | PXIe-4147 Specifications PXIe-4144. © National Instruments. com Introduction Editing Broadcast For more than 30. Refer to the NI website for an up-to-date list of known issues in. 0/7/Vista/XP, but MXI-3 is supported on only Windows XP. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. Leading Time:IN STOCK . Likewise, in the 100 mA range, resolution can be calculated by multiplying 100 mA by 100 ppm, as shown. Work with our experts to sustain your critical applications. Configuration: •Number of SMU Channels: 4. 5 A from the 3. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 5 driver. 53 GHz Intel Core 2 Duo processor or equivalent. 08-04-2022 12:25 PM. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1. PXIE-2575 NI module, NI, PXIE-2575 NI module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. •Voltage Range: -6 V to 6 V. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. the PXIe-4142. The PXIe-5842 combines a vector signal generator and vector signal analyzer with FPGA-based, real-time signal processing and control. Hi, I'm trying to trigger analog input measurements (PXIe-6363) with my SMU (PXIe-4142). It is possible to combine two SMU channels in parallel for higher current, however, this may cause performance issues in certain situations, and the instrument specifications are not guaranteed. Figure 1. 8 MS/s, giving you the ability to examine the detailed transient characteristics of the SMU output. Refer to the Combining Multiple Outputs section of NI-DCPower Help for information about connecting multiple NI PXIe-4112/4113 channels together for extended output. The NI PXIe-4140 has 4 quadrants; each channel has. Minimum order of 1 items Multiples of 1 only Please enter a valid quantity. en. Added support for the PXIe-4139(40W) source measure unit, newly supported in NI-DCPower 20. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Restricted Item . GETTING STARTED GUIDE PXIe-4162 PXIe, 12-Channel, ±24 V, 100 mA PXI Source Measure Unit This document explains how to install, configure, and test the PXIe-4162. 尽管未将DCPower和SMU卡(如PXIe-4139)设计为用作功能或波形发生器,但可以通过将所需的频率和幅度或预定义的. View context help in LabVIEW by pressing <Ctrl-H> and hovering over an object. 15 days free replacement for quality problemsWe have 2 National Instruments NI PXIe-4082 manuals available for free PDF download: Calibration Procedure, Getting Started Manual National Instruments NI PXIe-4082 Calibration Procedure (28 pages) PXIe, 6 1/2-Digit, +/-300 V, Onboard 1. pxie-2512 PXIE-1435 Company advantage service: 1. With a national network of resources, a robust quality program and broad capabilities, we offer standard and custom solutions to deliver fast, accurate calibration when and how it's needed. If you need to configure the current limit for your SMU devices, you can use niDCPower Configure Current Limit VI and niDCPower Configure Current Limit Range VI . In. The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files; Four-quadrant source and measure capability; Up to 408 channels in a 4U, 19-inch PXI chassis;The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. This document explains how to install, configure, and test the NI PXIe-4140/4141/4142/4143/4144/4145 (NI 414x). Before proceeding, ensure that a compatible version of NI-DCPoweris installed on the development PC. This process involves using the NI-DCPower VIs to export the SMU signal onto a PXI_TRIG line. 153690B-01L 782430-01 NI PXIE-4142 4-CHANNEL SMU: 24V,150MA 153690B-02L 782431-01 NI PXIE-4143 4-CHANNEL PRECISION SMU: 24V,150MA 153697C-01L 782432-01 NI PXIE-4144 4-CHANNEL SMU: 6V, 500MA 153697C-02L 782435-01 NI PXIE-4145 4-CHANNEL PRECISION SMU: 6V, 500MA Contact Information Please do not. Hey guys, I have one set of NI PXI Platform, the PXI chassis is PXIe-1082, and there're several cards inside it, such as PXIe-6570, PXIe-6368 and PXIe-4142. Hello, i am trying to measure capacitance with a SMU. 2. 10 20 Hz to 20 MHz bandwidth. 2. Diversified models and products, and all kinds of rare and discontinued products 4. As an example, assume you are using a PXIe-4139 in Single Point source mode. •Current Range: -3 A to 3 A. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. •Voltage Range: -200 V to 200 V. The problem is that the result changes with. 1 0. If you are not able to upgrade to NI-DCPower 18. Stock # 95045-4. The PXIe-4143 (Part Number: 782431-01) Source Measure Unit (SMU) incorporates a utility channel that can supply current or voltage with a 16-bit setpoint and an estimation resolution. We have to consider that current can flow between channels through common LO. 0 A from the 12 V rail PXIe-4142 (20W) 2. 10-17-2020 07:58 AM. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 2. 0 A from the 3. Table 1. PXIe-4142 Quadrant Diagram, All Channels Quadrant I Source I± ±24 V 150 mA I+ V± V+ 24 V Quadrant IV Sink Quadrant III Source ±150 mA Quadrant II Sink Limit power sinking to 6 W per module. The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Each 1+ RM76,925. Solution. NI InstrumentStudio 2022 Q1 Readme. Hardware PXI-4130 PXI-4132 PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 PXIe-4140 PXIe-4141 PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 PXIe-4162. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. CREATE. Has been engaged in industrial control industry for a long time, with a large number of inventories. 如何使用?. •Source Adapt: No. 92 [] 2X . PXIe-4143 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 32 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). For voltage >60 V DC and triaxial connectivity, consider the PXIe-4135 SMU with native triaxial connectors. This is not an exhaustive list of. 如果. Windows Server 2016 64-bit. Has been engaged in industrial control industry for a long time, with a large number of inventories. MODULE ASSEMBLY,PXIE-4142. We have 1 National Instruments PXIe-4610 manual available for free PDF download: Getting Started Manual. 11. Output Current Drive, Min A pk A rms * ±0. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. You can find the pinouts at the end of the PXIe chassis user manual based on your model. 2 Channels are isolated from earth ground but share a. Email: info@artisantg. Email: info@artisantg. PXIe-4145. 2 Channels are isolated from earth ground but share a. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Note Windows users may see access and security messages during installation. The measurement aperture time (the amount of time spent resolving each measurement) is defined in the help docs ("Properties Supported by the PXIe. 7 A from the 12 V rail. Manuals. Re: Recommended approach for PXI control from Python. Diversified models and products, and all kinds of rare and discontinued products 4. NI-PXIe-4142 Datasheet 305. •Current Range: -100 mA to 100 mA. 150660B-02L or later PXIe-4141 Flex SMU: 10V, 100 mA 150660B-03L or later PXIe-4141 Flex SMU: 10V, 100 mA w/ High Sense Resistance 153690A-01L or later PXIe-4142 Flex SMU: 24V, 150 mA 153690A-02L or later PXIe-4143 Flex SMU: 24V, 150 mA 153697A-01L or later PXIe-4144 Flex SMU: 6V, 500 mA 153697A-02L or later PXIe-4145 Flex SMU:. Add. the PXIe-4142. You can also view context help for the search results. Solution Although the DCPower and the SMU cards like the PXIe-4139 were not designed to be used as a function or waveform generator, it is possible to program the card to output standard functions by translating the desired frequency and amplitude or a predefined arbitrary waveform to a continuous output sequence with voltage levels and source delays (corrected by the intersample delays of the. Email: info@artisantg. The PXIe-4137 is a high-precision, system source measure unit (SMU). This file contains installation instructions and compatibility information for InstrumentStudio 2022 Q4. You can access the software and documentation known issues list online. com Problems encountered when allocating large buffers for serial. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Item Number : PXIe-4142. NI-DCPower 문의사항 공급할 수 있는 전압의 양을 늘리기 위해 NI의 소스 측정 장치 (SMU)를 2개 이상 계단식으로 연결하고 있습니다. 9 To recover within ±20 mV after a load current change from 10% to 90% of range. ni pxie-4142 ni pxi-5122 ni pxie-6536 ni pxi-4130 ni pxie-5672 ni pxi-5406 ni pxi-2534 ni pxi-5670 ni pxi-2501 ni pxie-6537 ni pxi-4110 ni pxi-5671 ni pxi-2503 ni pxi-5402 ni pxie-5641r ni pxie-2532b ni pxie-5450 ni pxi-5661 ni pxi-5142 ni pxi-2532b ni pxi-2529 ni pxi-5650 ni pxie-5451 ni pxi-5105 ni pxi-5651 ni pxi-2564the PXIe-4144. 6 GHz) PXIe-5673: PXIe-5673E (6. Phone: (217) 352-9330. 7 20 Hz to 20 MHz bandwidth. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. Four-Channel SMU. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. 148 3. 76 []. 1. PXIe-5162 Single-Tone Spectrum, 2. 6 W-24 V to 24 V:Phone: (217) 352-9330. custom applications within an application programming interface (API). The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 6 W: 3. •Current Sesitivity: 10 fA. •Voltage Range: -200 V to 200 V. Find new, used, and rental NI PXIe-4139 PXIe-4139 System SMU with Source Adapter Technology 782856-02 at Electro Rent. NI-DCPower 问题详述 我想使用源测量单元(SMU)生成正弦波信号或任意波形的电压或电流波形。. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 553. 2 Channels are isolated from earth ground but share a. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Channels are isolated from each other and from chassis ground. View and Download National Instruments NI PXIe-4140 getting started manual online. CU_PXIE-4142 2X #4-40 2X . 10-17-2020 07:58 AM. 9 To recover within ±20 mV after a load current change from 10% to 90% of range. Part Number: 782856-02. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. You can see which NI PXI Source Measure Units support SourceAdapt technology, by visiting the NI online catalog and filtering by SourceAdapt. PXIe-4142 Quadrant Diagram, All Channels. 115 2. This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source Measure Unit (SMU). This SMU is perfect for large pin applications. 45]. are not included with this equipment unless. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant. Although the DCPower and the SMU cards like the PXIe-4139 were not designed to be used as a function or waveform generator, it is possible to program the card to output standard functions by translating the desired frequency and amplitude or a predefined arbitrary. Module Installation 2 3 NI PXIe-1075 1 1. Refer to PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Options. 6. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1. View in Order History. TobiasG. 7 20 Hz to 20 MHz bandwidth. Table 4. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. 2. PXIe-4142 (782430-01) PXI Express: 4: 3. Re: Waveform capture on PXI-4142. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The PXIe-5841 is a vector signal transceiver (VST) with 1 GHz of instantaneous bandwidth. [email protected] MS/s. For example Ch0 can sink current from Ch2, but as all channels are configured in source mode then this is not correct working regime for the device, which can cause the damage of the channel. The fast sample rate of the PXIe-4145 can reduce measurement times. Note Before you begin, install and configure your chassis and controller. Has been engaged in industrial control industry for a long time, with a large number of inventories. Now, when you go to the Modules tab, you will notice that the incompatible cards are grayed out. Four-Channel SMU. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. •Voltage Range: -200 V to 200 V. cal is the internal device temperature recorded by the NI 4142 at the completion of the last self-calibration. 5 A from the 3. PXIe-1082. It includes the Digital Pattern Editor for configuring pin maps, specifications, levels, timing, and patterns. Industry leading, price advantage, quality assurance 3. The NI PXIe-4142 has Free Ground Shipping and a 1-3 Year Warranty, depending on New,. Email: info@artisantg. Measured at the end of the 1 m SHDB62M. This adapter is rated for 60 V DC maximum voltage and is not a recommended accessory for the PXIe-4136 or PXIe-4137 due to the 200 V DC output of those SMUs. 0 A from the 12 V rail PXIe-4142 (20W) 2. 7 A from the 12 V rail. 47 [] 2X . I have made a program where the capacitor is first discharged, then fed a constant current. You previously purchased this product. The equation is C=i*t/U. Solution Although the DCPower and the SMU cards like the PXIe-4139 were not designed to be used as a function or waveform generator, it is possible to program the card to output standard functions by translating the desired frequency and amplitude or a predefined arbitrary waveform to a continuous output sequence with voltage levels and source delays (corrected by the intersample delays of the. Four-Channel SMU. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PXIe-4142 (782430-01) PXI Express: 4: 3. NI‑DCPower 19. Even when following the above recommendations, combining channels can still present issues with noise, stability, and outputting the proper voltage/current. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. This page documents all the applicable standards and certifications for the PXIe-4142 and provides downloadable certifications. PXIe-4142 User Manual(s) PXIe-4142 Getting Started Guide(s) PXIe-4142 Calibration Procedure(s) Visual Diagrams . Current Limit Range VI decides the resolution, while Current Limit VI defines limit. Find new, used, and rental NI PXIe-4139 PXIe-4139 System SMU with Source Adapter Technology 782856-02 at Electro Rent. Environment. PXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, and PXIe-4139. Electro Rent Remains Ready and Available to Support Customers Through COVID-19 Challenges. 6 | ni. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source Measure Unit (SMU). From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PXIe-4496 NI module, NI, PXIe-4496 NI module Brand: General Electric Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. It is perfect for a wide scope of uses including manufacturing test. Although the DCPower and the SMU cards like the PXIe-4139 were not designed to be used as a function or waveform generator, it is possible to program the card to output standard functions by translating the desired frequency and amplitude or a predefined arbitrary. This documents provides information on calibration service levels available for NI Products. . NI-DCPower 21. Email: [email protected] PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. 6. PXIe-4142; PXIe-4143; PXIe-4144; PXIe-4145; PXIe-4154; Non-NI-DAQmx-Based Power Supplies and SMUs. Table 1. 0 A from the 3. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. 14142 0. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. 3V (there may be mistakes but I hope you get the idea). Fax: (240) 376-1381. PXIe-4142 Current Source and Sink Ranges Channels DC Voltage Ranges DC Current Source and Sink Ranges 0 through 3 ±24 V 10 μA 100 μA 1 mA 10 mA 150 mA Figure 1. The PXIe-4144 (Part Number: 782432-01) has a Wireless Testing System (RFIC) that incorporates the key instruments the user needs to describe control intensifiers, transceivers, IF receivers, RF fronts, modulators/demodulators, and other RFIC gadgets. PXIe-4142; PXIe-4143; PXIe-4144; PXIe-4145; NI 416x SMUs. NI PXIe-4140 control unit pdf manual download. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe is a standard that leverages the. The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. Fast Quotes & Shipping. PXIe-4162; PXIe-4163; Known Issues. 如何达到NI SMU的最大采样率?. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. PXI Express modules are not compatible with traditional PXI slots in a PXI chassis. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. 230 5. pxie-2512 PXIE-1435 Company advantage service: 1. Please contact Artisan Technology Group Sales for configuration pricing and availability. PXIe-4142 (782430-01) PXI Express: 4: 3. PXIe-4143 National Instruments PXIe-4143 Source Measure Unit (SMU) from National Instruments | Buy Today from Artisan. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. PXIe-4142. Chassis 2. 6 W: 3. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. PXIe-4142 PXIe-4143 PXIe-4144 PXIe-4145 This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source. Figure 1The PXIe-4112 is a single-quadrant power supply with two output channels that are capable of identical output. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. It features 4. •Voltage Range: -60 V to 60 V. 6 W: 3. 494 12. Device-specific information about these modules is included in the NI DC Power Supplies and SMUs Help. Follow the instructions in the installation prompts. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. National Instruments PXIe-4138 PXI Source Measure Unit. The AC power cord grounds the chassis and protects it from electrical damage while you install the PXIe-4162. The NI 414x is a four-channel source measure unit (SMU). Windows 10 64-bit. The PXIe-4162 ships with NI-DCPower driver software, which you can use to program the module. PXI System Source Measure Units. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。The PXIe‑6570 is designed for semiconductor characterization and production test. Find new, used, and rental NI PXIE-4138 PXI Source Measure Unit at Electro Rent. I have replaced my NI controller with Adlink' PXIe-3985, but self-test in Max has failed. This article will show how to achieve digitizer (scope) functionality and the maximum sample rate of your NI Source Measure Unit (SMU). View and Download National Instruments NI PXIe-4140 getting started manual online. Note Windows users may see access and security messages during installation. 6 W: 3. Has been engaged in industrial control industry for a long time, with a large number of inventories. TobiasG. Besides, it’s possible to examine each page of the guide singly by using the scroll bar. NI PXIe-4142 technical details. 4Channels PXIe-4142 Current/Voltage Measure, Current/Voltage. This way you’ll save time on finding the necessary info. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. If an application requires more voltage or current that can be provided by a single channel on a particular SMU, this article describes how to combine SMU channels to achieve higher voltage or. ni pxie-1085シャーシにおけるpxiトリガバスの接続図。 PXI周辺モジュールへのトリガの転送方法を表している。 電気的仕様では、高い性能が要求されるアプリケーションに向けて、PXIシステムに高性能の同期機能を加えるPXIスタートリガネットワークについて. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. These devices offer increased speed, accuracy, and synchronization features that are well suited for high-density sensor measurement and signal-conditioning systems. The fast sample rate of the PXIe-4144 can reduce measurement times,. Call the niDCPower Get Self Cal Last Temp VI to query Tcal from the NI 4142. I have replaced my NI controller with Adlink' PXIe-3985, but self-test in Max has failed. NI PXIe-414x family provides four source measurement unit (SMU) channels with each channel capable of sourcing or sinking power within its I-V operating range. Member Author ‎11-30-2017 02:54 AM. The NI PXIe-4142 has Free Ground Shipping and a 1-3 Year Warranty, depending on New, Reconditioned, Used, or Repair Status of the model. Buffered output that follows the voltage of the HI force. Configuration: •Number of SMU Channels: 24. com | NI PXIe-4142 Calibration Procedure. Depending on your current range, you can achieve this speed with anywhere from 1 nA of noise to 10 mA of noise. Ejector Handle in Down (Unlatched) Position 9. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. NI PXIe-4142 PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit This document contains the verification and adjustment procedures for the NI 4142. Diversified models and products, and all kinds of rare and discontinued products 4. Re: DCPower measuring multiple samples from multiple channels. The digitizer functionality of NI SMUs is essential for capturing detailed transient characteristics of the SMU response or for characterizing device under test (DUT) behavior such as line. The NI PXIe-4142/43 source measure units (SMUs) are high-channel-count, high-speed SMUs with four identical SMU channels per PXI Express slot. i am trying to measure capacitance with a SMU. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. The PXIe-5841 features the flexibility of a software defined radio architecture with RF. Fax: (240) 376-1381. 000 0 [] 5. The user can utilize this output, which gives up to 6 V and 1 A, as a complementary power supply to the. 66 KB NI-PXIe-4163 Datasheet 308. We are using a PXIe-6368 multifunction I/O module.